Quantcast
Channel: SCN: Message List
Viewing all articles
Browse latest Browse all 8526

Re: Performance Determination by Measuring point

$
0
0

Hello Experts,

 

 

A per my requirement I put break-point in User exit IMRC0001 in function module EXIT_SAPLIMR0_001 in include ZXMRCU01 but when I enter reading in measurement point entry list in IK34 or in IK11 to create measurement document it does not stop anywhere in Code and entry will get stored in system However a information message comes in status bar for reading falling outside upper and lower limits later on it get stored in system.

 

Actually I want to make my ABAP consultant understand on saving it should trigger notification(M2).

 

Please share your opinion

 

Thanks

Inderjeet


Viewing all articles
Browse latest Browse all 8526

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>